Shop

Immersion Heaters Zone 1/21

SPECIFICATIONS

Click to expand/collapse
Enclosure

Mild steel as standard - 316 stainless steel & painted options available on request

Element 316L stainless steel plain surface tube as standard – mild steel & extended surface available on request
Controls Heater over-temperature protection is fitted as standard (optional process temperature sensing devices can be incorporated in the form of thermostats, RTD's or thermocouples terminated within transmitters)
Mounting 3" NB 150lb ANSI RF Blind 316L stainless steel flange as standard. Any threaded NPT or BSP boss or flange in any material can be specified within the limits of the design parameters; heater terminal box can be either "direct-on" or "stand-off", depending on process temperature
Rating To suit process requirements within the design and certification parameters
Voltage Any electrical supply up to 690VAC (600V CSA) +0/-10% tolerance

FURTHER FEATURES

Dot
Certified to ATEX, CSA, CEc/NEC, CU TR, KGS, INMETRO, CNEx and IECEx standards
Dot
Mild steel or 316 stainless steel terminal enclosure with weatherproof protection to IP66 or Enclosure Type / NEMA 4 or 4X
Dot
Choice of built in process temperature sensors
Dot
Suitable for ambient temperatures from -60°C to +60°C (subject to cert parameters)
Dot
Mounting of the heater can be by a threaded NPT or BSP boss or an industry standard flange
Dot
Designed for horizontal installation (vertical mounting version available on request)
Dot
Can be supplied with the terminal box mounted away from the fixing boss / flange

APPROVALS

csm_LOG_ZUL_ATEX__SALL__AIN__V1_5c46efd86d
ATEX (Europe) approved
EX II 2 G/D Ex d IIC T1 to T6 Gb Zone 1 and 2
Ex tb IIIC T450°C to T85°C Db Zone 21 and 22 (IP66)
csm_LOG_ZUL_IECEx-Zulassung__SALL__AIN__V1_d87ccdfa51
IECEx (International) approved
EX II 2 G/D Ex d IIC T1 to T6 Gb Zone 1 and 2
Ex tb IIIC T450°C to T85°C Db Zone 21 and 22 (IP66)
csm_LOG_ZUL_CSA-Zulassung__SALL__AIN__V1_4f9c82bb2f
NEC500 (North America) approved
CSA (CEC/NEC) Class I, Div 1, Groups A, B, C, D; T1 to T6, Enclosure Type / NEMA 4 or 4X