Description
The standard heater consists of a single element or multiple cartridges fitted into a mounting flange. A robust Ex d terminal enclosure protects the electrical connections. The watts density of the element fitted depends upon the media to be heated and the kilowatt rating required.
The FP removable cartridge-type immersion heater range is certified for use in hazardous areas where the atmosphere is classified as a Zone 1 or 2 (IIA, IIB, IIC) gas group, or a Zone 21 or 22 (IIIA, IIIB, IIIC) dust group.
Features
- Certified to ATEX and IECEx standards
- Mild steel or 316 stainless steel terminal enclosure with weatherproof protection to IP66 or Enclosure Type / NEMA 4 or 4X
- Choice of built in process temperature sensors
- Suitable for ambient temperatures from -60°C to +60°C (subject to certification parameters)
- Mounting of the heater can be by a threaded NPT or BSP boss or an industry standard flange
- Designed for horizontal installation (vertical mounting version available on request)
- Can be supplied with the terminal box mounted away from the fixing boss / flange for high process temperatures
Specification
Certification | ATEX / IECEx ![]() ATEX / IECEx Ex tb IIIC T450°C to T85°C Db Zone 21 and 22 (IP66) CSA (CEC/NEC) Class I, Div 1, Groups A, B, C, D; T1 to T6, Enclosure Type / NEMA 4 or 4X CSA (CEC) Ex d IIC; T1 to T6 Gb, IP66 (CAN) CSA (NEC) Class I, Zone 1, AEx d IIC; T1 to T6 Gb, IP66 (USA) CU TR (EAC), KGS, CNEx, CCOE (CCEs), Inmetro |
---|---|
Enclosure | Mild steel or 316 stainless steel, external and internal earths, screwed terminal cover, finished in epoxy paint (if required) |
Elements | Removable 304/316L stainless steel cartridge, comprising high quality 80/20 nickel chrome resistance wire, housed within 316L stainless steel sheath; cartridges secured by welding |
Controls | Heater over-temperature protection is fitted as standard (optional process temperature sensing devices can be incorporated in the form of thermostats, RTD’s or thermocouples) |
Mounting | Any threaded boss or flange in any material can be specified within the limits of the design parameters; heater terminal box can be either ‘direct-on’ or ‘stand-off’, depending on process temperature |
Rating | To suit process requirement within the design and certification parameters |
Voltage | Any electrical supply up to 690V (600V CSA) |